1Overview

Modify infrADAC installation transfers the active installation to another supported host profile, creates an additional copy without changing the active Windows registration or recalls the local licence activation. It is launched from the registered Windows app entry and uses the current updater.

Transfer and Copy Install are not the same

Transfer changes the active host target and Windows registration. Copy Install duplicates the files and leaves the current registered installation unchanged.

2Open Modify

  1. Save work and close active CAD sessions.
  2. Open Windows Settings.
  3. Go to Apps > Installed apps.
  4. Locate infrADAC, open its app actions and select Modify.
  5. Wait for Modify infrADAC installation to open.
Windows Installed apps showing the infrADAC Modify action
Image placeholderWindows Modify actionShow infrADAC in Installed apps and the Modify option.PLACEHOLDER_IMAGE_URL_MODIFY_WINDOWS_ENTRY
Use the registered Modify action rather than launching the updater with custom arguments.
Modify infrADAC installation window
Image placeholderModify infrADAC installationShow current install, current host target, host choice, selected target and action buttons.PLACEHOLDER_IMAGE_URL_MODIFY_FORM
The current installation and target appear as read-only values.

3Transfer or copy the installation

Step 1 of 6
01

Review the current installation

Confirm the source before selecting a new host target.

  • Check Current install.
  • Check Current host target.
  • If either value is unexpected, close Modify and confirm which Windows app entry was opened.
The updater resolves its parent application root

When Modify starts from the installed Update folder, it treats the parent infrADAC folder as the source.

4Accepted target folders

ProductAccepted selectionResolved targetValidation
infrADAC ACADAutoCAD install folder, local R* profile folder or local enu folder.The matching local AutoCAD enu profile where available.acad.exe, AutoCAD 2025 or newer.
infrADAC BCADBricsCAD install folder, local V*x64 profile or locale folder.The matching local BricsCAD locale profile.bricscad.exe, BricsCAD 2026 or newer.
infrADAC DCAD12d install root or its nt.x64 folder.The parent 12d install root.Recognised 12d executable in the selected folder or nt.x64.
DCAD has two deployment destinations

The infrADAC application root remains under Program Files. Modify also merges the owned toolbar and macro payload into the selected 12d install and derived user-path roots while preserving unrelated toolbar entries.

5Transfer compared with Copy Install

BehaviourTransferCopy Install
Copies the application treeYesYes
Changes the registered current installYesNo
Updates ACAD/BCAD startup loaderYesNo
Applies DCAD toolbar payloadYesYes
Removes the source folderNo guaranteed source deletionNo

6Uninstall Licence

This action removes the active local licence from the computer and asks the server to recall the activation. It does not uninstall infrADAC application files.

  1. Select Uninstall Licence.
  2. Read the warning and select OK.
  3. Wait for the server response.
  4. Keep the displayed result for support if recall is unsuccessful.
Seven-day recall restriction

The confirmation states that a licence cannot be recalled again within seven days unless support completes it. Use the action only when the activation genuinely needs to move or be released.

Uninstall Licence confirmation in the Modify window
Image placeholderUninstall Licence confirmationShow the recall warning and OK/Cancel controls.PLACEHOLDER_IMAGE_URL_MODIFY_UNINSTALL_LICENCE
Full application removal is covered by the Uninstalling infrADAC guide.

7Troubleshooting

No installation is detected in the selected folder

Select the folder containing the expected CAD executable or an accepted local profile folder. For 12d, select the install root or nt.x64.

The target host version is unsupported

Use AutoCAD 2025 or newer or BricsCAD 2026 or newer. The host version must be detectable from its folder or executable metadata.

The transfer or copy fails

Close all CAD hosts, confirm both source and destination are writable and retry. The destination cannot be inside the current infrADAC application folder.

The ribbon or toolbar is still missing

For ACAD or BCAD, run ADACCUIX after confirming the correct local profile was selected. For DCAD, restart the 12d project after toolbar changes and verify the correct 12d version folder was used.

%LOCALAPPDATA%\InfrADAC\Updates\Logs\infrADAC_Updater_yyyyMMdd_HHmmss.log