1Overview

The current Clean form is a multi-action repair tool. It can renumber/revalue ADACIds, audit/fix InfrastructureCode GUIDs, validate the supporting-files cache, recalculate elevation/length/area prefills and recreate or refresh property blocks.

Use this guide when

Audit reports duplicates or invalid GUIDs, files were moved, geometry changed after prefilling, or labels are missing/stale.

2Run controlled repair actions

Back up, select a narrow repair set, read the log and audit again.

Step 1
01

Choose scope

Limit the scan to project extents or the full model.

  1. Run ADACClean.
  2. Select Extents when the saved boundary is reliable, or Model Space for a full scan.
  3. Review the asset count and current project context.
Choose scope in the current infrADAC interface
Image placeholderChoose scopeShow the current infrADAC interface and result for: Limit the scan to project extents or the full model.PLACEHOLDER_IMAGE_URL_CLEAN_AND_REPAIR_STEP_01
Choose scope shown at this exact stage of the task.

3Clean action matrix

Each checkbox changes a different data surface and has a different recovery path.

Feature or choiceCurrent behaviour
ADACId repairScans identities, revalues duplicates/invalid entries and updates supporting-file folders/XData for changed IDs.Identity integrity and attachments stay aligned.
InfrastructureCodeResolves required GUID state from effective definitions and audits/fixes values.Receiver codes meet schema expectations.
Prefill recalculationComputes geometry-derived elevation, length or area and writes only changes above the configured unit-aware threshold.Minor CAD noise does not cause unnecessary data churn.
Property blocksRecreates missing blocks and refreshes all relevant blocks from XData.Visible asset presentation is repaired after data changes.

4Before you begin

  • Create a backup of the drawing/project and supporting-file cache.
  • Run audit first and record the issues you intend to repair.
  • Choose Extents or Model Space scope deliberately.

5Product differences

The task is shared where possible, but selection, interface integration and model operations follow the host shown below.

infrADAC ACAD

Runs against AutoCAD model space or saved extents and can repair DWG property blocks.

6Troubleshooting

Clean reports skipped assets

Read the per-asset reason in the log. Missing schema identity, unsupported geometry or unreadable XData usually requires Edit, Generate or profile repair.

Calculated values did not update

Confirm the asset definition includes the field in PropertiesToPrefill, drawing units are known and the change exceeds the configured threshold.

Audit has more issues after Clean

Restore the backup if needed, then rerun only the repair that addressed the original issue. A profile mismatch can make a technically correct rewrite fail receiver validation.