Fitting

Element representing a sewer fitting other than a valve.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
Type enum
Required

The physical configuration of the fitting.

Accepted Values
ValueDescription
Bend Bend fitting usually with change of direction of more than 11 degrees but may be less in plastic pipes.
Connector Straight connector with no direction change.
ConnectorThrust Straight connector capable of transmitting axial thrust.
DismantlingJoint Straight connector specifically included to facilitate future dismantling of pumps or complex pipe layouts.
DuckBill Duck Bill fitting typically located at the end of a pipe feature.
FrogFlap Frog Flap fitting typically located at the end of a pipe feature.
Gibault Standard gibault connection.
Taper Fitting with differing inlet and outlet diameters.
Tee Tee-fitting with 3 arms or branches where one arm is at 90 degrees to the other 2.
Wye Y-fitting with three arms where the arms is are not all separated by integer multiples of 90 degrees.
CathodicProtectionPoint An electrical connection point for cathodic protection.
DeadPlate A Dead Plate or blank flange secured to one arm of another fitting.
ExternalDeadEnd An external fitting incorporating a dead end such as a dead end cap.
TeeBranchDeadEnd A dead end plate pre-fitted to one branch of a Tee for access or future connection.
TeeBranchExtDeadEnd An end cap pre fitted externally to to a Tee Branch for access or future connection.
PuddleFlange A Puddle Flange fitted externally to a pipe to transmit axial thrust into a structure or to provide sealing with a structure.
SamplingPoint A point designed for taking sewage or effluent samples.
BoosterPump A pump providing the motive force to move sewage through a pressure main against the force of gravity.
InspectionOpening An Inspection Opening on a pressure pipe.
Material enum
Required

Fitting material.

Accepted Values
ValueDescription
ABS Acrylonitrile Butadiene Styrene.
Aluminium Aluminium
GRP Glass Reinforced Plastic (includes the product known commercially as Hobas).
DI Ductile Iron.
MS Mild Steel.
PE100 Polyethylene (100).
PE80B Polyethylene (80B).
PVC-M PolyVinylChloride (Modified).
PVC-O PolyVinylChloride (Oriented).
PVC-U PolyVinylChloride (Unplasticised).
Rubber Rubber
SS Stainless Steel.
VC Vitreous Clay.
Concrete Concrete
AC Asbestos Cement (Existing infrastructure only).
FRC Fibre Reinforced Concrete.
M_1 New material not included in schema as agreed with data recieiving entity.
M_2 New material not included in schema as agreed with data recieiving entity.
Unknown Material type unknown at time of data submission.
Other A material not included in schema types provided above.
Lining enum
Optional

The internal corrosion protection material or method for the fitting.

Accepted Values
ValueDescription
CL Cement Lined Normal. Centrifugally spun cement mortar (default for Ductile Iron and Mild Steel).
CL_SR Cement Lined - Sulphate Resistant (DI and MS).
CL_AC Cement Lined - Calcium Aluminate (DI and MS).
PVC Plasticised PVC (includes Humes Plastiline).
FBE Fusion Bonded Epoxy.
Unlined Unlined (Default for plastic pipes).
Unknown Lining type unknown at time of data submission.
Other Another type of liner that is not currently in the Schema.
Protection enum
Optional

The external protection for the fitting.

Accepted Values
ValueDescription
FBE Fusion Bonded Epoxy.
FBPE Fusion Bonded Polyethelene (Includes the product known commercially as Sintakote).
PlasticWrapped PlasticWrapped
TapeWrapped Wrapped in pipe and flange protection anti-corrosion tape. Commonly a synthetic fabric tape coated with a neutral petrolium compound.
ConcreteEncased ConcreteEncased
Sheathed Sheathed
EpoxyPaint EpoxyPaint
Uncoated Uncoated
P_1 A new protection type not yet in the schema as agreed with the data receiving entity.
P_2 A new protection type not yet in the schema as agreed with the data receiving entity.
Zinc Galvanized or zinc painted.
ZincAluminiumAlloy Zinc Aluminium alloy coating (Petair Saint-Gobain).
Unknown Protection type unknown at time of data submission.
Other Another type of protection not covered by the schema.
BodySize_mm positiveInteger
Required

The nominal diameter of the major connecting pipe.

BranchSize_mm positiveInteger
Optional

The nominal diameter of the minor connecting pipe.

Rotation Float_Direction
Optional

Rotation angle (cartesian - anti-clockwise 0 degrees = East)