StructureID String_32
Required

The identifier for this end structure. Usually the textual identifier it would be labelled with on the face of a plan.

StructureLevel_m float
Required

The surface level of the structure in metres against the vertical datum for the project.

EndWall boolean
Required

Data structure representing the end wall. Set to nil if this End Structure does not have an end wall.

truetrue
Type enum
Required

The type of stormwater end wall structure.

Accepted Values
ValueDescription
Pipe Endwall Pipe Endwall
Box Endwall Box Endwall
MultiCell Pipe Endwall MultiCell Pipe Endwall
Multi Cell Box Endwall Multi Cell Box Endwall
Multi Cell Pipe and Box Endwall Multi Cell Pipe and Box Endwall
Sloping Pipe Endwall Sloping Pipe Endwall
Size String_32
Required

Define the number of cells and sizes penetrating the End Structure. ie. 3/750 or 2/1200x900 or 2/900x600+1/600.

Length_m Float_Positive_Zero
Required

Represents the length in metres of the end wall.

Height_m Float_Positive_Zero
Required

Represents the height in metres of the end wall.

Thickness_m Float_Positive_Zero
Required

Represents the Thickness in metres of the end wall.

Material enum
Required

The predominant construction material of the end wall structure.

Accepted Values
ValueDescription
Concrete Concrete
Reinforced Concrete Reinforced Concrete
Grouted Rock Grouted Rock
Revetment Mattress Revetment Mattress
N/A Not Applicable – To be used if not present
Construction enum
Required

The method of construction of the end wall structure.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
WingWall boolean
Required

Data structure representing the wing wall. Set to nil if this End Structure does not have any wing walls.

truetrue
LWW_Length_m Float_Positive_Zero
Required

Represents the length in metres of the left wing wall.

LWW_Height_m Float_Positive_Zero
Required

Represents the height in metres of the left wing wall.

LWW_Thickness_m Float_Positive_Zero
Required

Represents the thickness in metres of the left wing wall.

LWW_Material enum
Required

The predominant construction material of the left wing wall.

Accepted Values
ValueDescription
Concrete Concrete
Reinforced Concrete Reinforced Concrete
Grouted Rock Grouted Rock
Revetment Mattress Revetment Mattress
N/A Not Applicable – To be used if not present
LWW_Construction enum
Required

The method of construction of the left wing wall.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
RWW_Length_m Float_Positive_Zero
Required

Represents the length in metres of the right wing wall.

RWW_Height_m Float_Positive_Zero
Required

Represents the height in metres of the right wing wall.

RWW_Thickness_m Float_Positive_Zero
Required

Represents the thickness in metres of the right wing wall.

RWW_Material enum
Required

The predominant construction material of the right wing wall.

Accepted Values
ValueDescription
Concrete Concrete
Reinforced Concrete Reinforced Concrete
Grouted Rock Grouted Rock
Revetment Mattress Revetment Mattress
N/A Not Applicable – To be used if not present
RWW_Construction enum
Required

The method of construction of the right wing wall.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
Apron structure
Required

Data structure representing the apron.

StructureStructure
Apron_Width_m Float_Positive_Zero
Required

Represents the width in metres of apron on the End Structure.

Apron_Thickness_m Float_Positive_Zero
Required

Represents the thickness in metres of apron on the End Structure.

Apron_Area_m2 Float_Positive_Zero
Required

Represents the area in square metres of apron on the End Structure.

Apron_Material enum
Required

The predominant construction material of apron on the End Structure.

Accepted Values
ValueDescription
Grassed Grassed
Concrete Concrete
Stone Pitched Stone Pitched
Placed Rock Placed Rock
Grouted Rock Grouted Rock
Revetment Mattress Revetment Mattress
Rock Filled Wire Basket Rock Filled Wire Basket
Geotextile Geotextile
Concrete Energy Dissepiment Concrete Energy Dissepiment
N/A Not Applicable – To be used if not present
Apron_Construction enum
Required

The method of construction of apron on the End Structure.

Accepted Values
ValueDescription
Prefabricated Prefabricated
Insitu Built or poured in-situ
GrateType enum
Optional

Type of grate used, if applicable.

Accepted Values
ValueDescription
Baffled Baffled
Grated Grated
Stilling Basin Stilling Basin
None No grate fitted
TideGate enum
Optional

Type of tide or flood gate used, if applicable.

Accepted Values
ValueDescription
Fibreglass Proprietary Fibreglass Proprietary
Fabricated Fabricated
Controlled Controlled
Rubber Rubber