StormWater / ADAC Version v4.1

GPTComplex

Represents a complex commerial or custom StormWater Quality Improvement Device (SQID).

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
Sqid_Id String_32
Optional

The string identifier of the device, as it would appear on a plan.

Construction enum
Required
CommercialCommercial
Manufacturer String_64
Required

The manufacturer of the unit.

Model String_64
Required

The unit model code.

Size enum
Required

Construction

RectangularPlanimetric dimensions of a rectangular device.
Length_mm positiveInteger
Required

Length in millimetres.

Width_mm positiveInteger
Required

Width in millimetres.

Function1 enum
Required

The first function of the WSUD point. The device must have at least one function. Usually Gross Pollutant Capture will be the most important function.

Accepted Values
ValueDescription
GrossPollutantCapture GrossPollutantCapture
SedimentCapture SedimentCapture
OilGritSeparation OilGritSeparation
Filtration Filtration of fine particulates from stormwater before discharging to a downstream drainage system.
Function2 enum
Optional

The second function of the WSUD point, if applicable.

Accepted Values
ValueDescription
GrossPollutantCapture GrossPollutantCapture
SedimentCapture SedimentCapture
OilGritSeparation OilGritSeparation
Filtration Filtration of fine particulates from stormwater before discharging to a downstream drainage system.
Function3 enum
Optional

The third function of the device, if applicable.

Accepted Values
ValueDescription
GrossPollutantCapture GrossPollutantCapture
SedimentCapture SedimentCapture
OilGritSeparation OilGritSeparation
Filtration Filtration of fine particulates from stormwater before discharging to a downstream drainage system.
US_PipeDiameter_mm positiveInteger
Optional

The upstream pipe diameter in millimetres.

DS_PipeDiameter_mm positiveInteger
Optional

The downstream pipe diameter in millimetres.

SurfaceLevel_m float
Required

The surface level at the top of the device.

DimensionsInvertLevels_m structure
Required

Calls in the standard elements for upstream and downstream invert levels.

StructureStructure
US_InvertLevel_m float
Required

Invert level in metres AHD of this pipe end.

DS_InvertLevel_m float
Required

Invert level in metres AHD of this pipe end.

CleanoutLevel_m float
Required

The level to which the device must be cleaned out, in metres against the vertical datum of the project.

Depth_m Float_Positive_NonZero
Required

The depth, in metres, of the device.

SumpDepth_m Float_Positive_NonZero
Required

The depth, in metres, of the sump, if applicable.

HasFilterMedia boolean
Required

True if the device has filtration media or a filter capsule installed.

HasBasket boolean
Required

True if the device has a litter basket installed.

HasBoards boolean
Optional

True if the device has drop-boards or penstock installed.

DesignFlow_m3s Float_Positive_NonZero
Required

Design Flow in cubic metres per second.

MaxContaminantVolume_m3 Float_Positive_NonZero
Optional

Maximum contaminant retention volume in cubic metres.

MaintenanceCycle_mnths positiveInteger
Optional

The minimum maintenance cycle in months (refer to specifications).

Rotation Float_Direction
Optional

Rotation angle (cartesian - anti-clockwise 0 degrees = East)