The fitting type.
WaterSupply / ADAC Version v4.2
ADAC
Fitting
Represents a water supply pipe fitting, other than a valve, meter or hydrant.
ADAC Versions
Attributes
Required and optional XML attributes
Type
enum
Required
ValueDescription
Bend
Bend, a fitting not a recurved pipe that changes the direction of a pipeline.
Connector
A straight through connector with no change of direction.
Cross Connection
A cross connection with 4 branches.
Connector Thrust
A straight through connector with no change of direction capable of transmitting axial thrust to the pipeline or a structure.
Dismantling Joint
A straight connector specifically included to facilitate the dismantling of complex flanged pipework and valves.
Gibault
Standard gibault connection.
Taper
Taper. Joining pipes of unequal diameter.
Tee
T - Joint with 3 arms one of which is at right angles to the axis joining the other 2.
Wye
Y - Joint with 3 arms where the angle between any 2 arms is not 90 or 180 degrees.
Cathodic Protection Point
Electrical connection point for cathodic protection.
Dead Plate
Blank flange on the end of a flanged pipe or fitting.
External Dead End
Fitting such as an endcap that forms a dead end in a pipe run.
Tee Branch Dead End
A dead end plate pre-fitted to one branch of a Tee for access or future connection.
Tee Branch Ext Dead End
Dead end on a Tee fitting with a side branch of extended length.
Puddle Flange
Puddle Flange on pipe to transmit thrust or seal pipe into a structure.
Ready Tap
Ready Tap collar with prefabricated water service take off points.
Sampling Point
Sampling Point to sample water quality.
Booster Pump
Booster Pump to boost pressure or provide motive force to water in the network.
Material
enum
Required
The fitting material.
Accepted Values
ValueDescription
DICL
Ductile Iron Concrete Lined.
PVC
Poly Vinyl Chloride.
Lining
enum
Optional
The internal corrosion protection method employed on the fitting material.
Accepted Values
ValueDescription
CL
Cement Lined normal (default for Ductile Iron and Mild Steel).
CL_SR
Cement Lined - Sulphate Resistant (DI and MS).
CL_AC
Cement Lined - Calcium Aluminate (DI and MS).
PVC
PolyVinylChloride.
FBE
Fusion Bonded Epoxy.
Unlined
Unlined
Unknown
Lining type unknown at time of data submission.
Other
Another type of liner that is not currently in the Schema.
Protection
enum
Optional
The external corrosion protection method employed on the fitting material.
Accepted Values
ValueDescription
FBE
Fusion Bonded Epoxy.
FBPE
Fusion Bonded Polyethelene (Includes the product known commercially as Sintakote).
Plastic Wrapped
Plastic Wrapped
Concrete Encased
Concrete Encased
Tape Wrapped
Wrapped in pipe and flange protection anti-corrosion tape. Commonly a synthetic fabric tape coated with a neutral petrolium compound.
Uncoated
Uncoated
Epoxy
Epoxy paint or coating.
P_1
A new protection type not yet in the schema as agreed with the data receiving entity.
P_2
A new protection type not yet in the schema as agreed with the data receiving entity.
Zinc
Galvanized or zinc painted.
Zinc-Aluminium Alloy
Zinc Aluminium alloy coating (Petair Saint-Gobain).
Unknown
Protection type unknown at time of data submission.
Other
Another type of protection not covered by the schema.
BodySize_mm
positiveInteger
Required
The nominal diameter of the largest pipe entering the fitting. Although not constrained, software may use the simpleType water_fittings_boresize for a starting list of values
BranchSize_mm
positiveInteger
Optional
The nominal diameter of the smallest pipe entering the fitting. Although not constrained, software may use the simpleType water_fittings_boresize for a starting list of values
Rotation
Float_Direction
Optional
Rotation angle (cartesian - anti-clockwise 0 degrees = East)
WaterQuality
enum
Required
The quality of the water being carried by the network to which the fitting is a part.
Accepted Values
ValueDescription
Drinking Water
Drinking-quality (potable) water for normal mains supply by the municipal water service provider.
Recycled Aplus
Class A+ tertiary treated with reverse osmosis recycled water for supply via dual reticulation for permitted interior and exterior uses.
Recycled A
Class A tertiary treated recycled water for supply via dual reticulation for permitted exterior uses.
Treated Effluent
Treated Effluent to class B through class D for irrigation only.
Rain Water
Rain Water collected directly into the system for irrigation.
Raw Water
Untreated water from a watercourse or pond used to feed a water treatment plant or irrigation system.
Ground Water
Untreated water from bores used to feed a water treatment plant or irrigation system.
Process Water
Non-potable process water of some description.
Other
Pipe conveying some other kind of water (not recycled class B and below which is considered as treated sewage effluent).
Unknown
Type of water carried by this pipe is unknown at time of submission.