WaterSupply / ADAC Version v5.0.1

ServiceFitting

Represents a water service fitting feature.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
Type enum
Required

The type of valve.

Accepted Values
ValueDescription
ControlPanel Irrigation control panel which may or may not be hydraulically connected.
DogBowl Fixed animal drinking bowl attached to customer owned water connection.
DrinkingFountain Drinking Fountain or bubbler to provide drinking water to patrons.
DripLine Fixed perforated pipe for drip irrigation.
FountainDecorative A decorative fountain.
FillingStation Card-accessed water delivery point for commercial access.
Filter In line filter to prevent irrigation line blockages.
GooseNeck Downward pointing outlet on a vertical riser.
HotWaterSystem Hot Water System. Normally attached to a structure.
Nipple Simple riser or short length of small bore pipe providing a point of discharge.
Other Some other irrigation fitting - do not use for pipe fittings, valves pumps etc as these exist in other feature classes.
PopUpSprinkler Pop-up type sprinkler head.
Shower Open air public shower point, such as may be found at beachside parks.
SprayNozzle Fixed Irrigation sprayer, sprinkler, bubbler or drip nozzle.
Tap Water delivery tap. Not a stopcock or control valve.
BelowGround boolean
Optional

Is the fitting below ground.

WaterSaver boolean
Optional

Does the fitting employ waste minimisation technology (other than auto shut-off).

AutoShutOff boolean
Optional

Does the fitting employ auto shut-off technology.

Rotation Float_Direction
Optional

Rotation angle (cartesian - anti-clockwise 0 degrees = East)

WaterQuality enum
Required

The quality/source of the water being supplied through the service fitting.

Accepted Values
ValueDescription
DrinkingWater Drinking-quality (potable) water for normal mains supply by the municipal water service provider.
RecycledAplus Class A+ tertiary treated with reverse osmosis recycled water for supply via dual reticulation for permitted interior and exterior uses.
RecycleA Class A tertiary treated recycled water for supply via dual reticulation for permitted exterior uses.
TreatedEffluent Treated Effluent to class B through class D for irrigation only.
RainWater Rain Water collected directly into the system for irrigation.
RawWater Untreated water from a watercourse or pond used to feed a water treatment plant or irrigation system.
GroundWater Untreated water from bores used to feed a water treatment plant or irrigation system.
ProcessWater Non-potable process water of some description.
Other Pipe conveying some other kind of water (not recycled class B and below which is considered as treated sewage effluent).
Unknown Type of water carried by this pipe is unknown at time of submission.