Sewerage / ADAC Version v5.0.1

Connection

Element representing a sewer property connection.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
SurfaceLevel_m float
Required

Surface level of this feature (in metres against the vertical datum).

InvertLevel_m float
Required

Invert level of this feature (in metres against the vertical datum).

Use enum
Required

The function of the house connection in the network..

Accepted Values
ValueDescription
House House Drain - standard sanitary drain conveying sewage only.
Combined Combined House Drain - a sanitary drain conveying both sewage and storm water in a combined sewerage system.
Diameter_mm positiveInteger
Required

The nominal diameter of the connection conduit.

Material enum
Required

The material of the connection conduit.

Accepted Values
ValueDescription
PVC-U PolyVinylChloride (Unplasticised).
PVC-M PolyVinylChloride (Modified).
PVC-O PolyVinylChloride (Oriented).
CastIron CastIron
RCP Steel Reinforced Concrete Pipe.
DI Ductile Iron.
FRC Fibre Reinforced Concrete.
FRP Fibre Reinforced Plastic.
PE Polyethylene.
VC Vitrified Clay.
M_1 New material not included in schema as agreed with data recieiving entity.
M_2 New material not included in schema as agreed with data recieiving entity.
Unknown Material type unknown at time of data submission.
Other A material not included in schema types provided above.
Class enum
Required

The pipe class as specified by the manufacture. Pipe class refers to the wall thickness and performance of the material.

Accepted Values
ValueDescription
SH Sewer Heavy.
SEH Sewer Extra Heavy.
SN4 Class SN4.
SN6 Class SN6.
SN8 Class SN8.
SN10 Class SN10.
SN12 Class SN12.
SDR21 SDR21
Unknown Unknown at time of submission.
Other Some other class not included in the standard Schema.
Length_m Float_Positive_NonZero
Required

The material length in metres of the house connection branch conduit.

Type enum
Required

The physical configuration of the valve.

Accepted Values
ValueDescription
SlopedBranch Sloped Branch connection.
RampRiser Ramp Riser connection.
JumpUp Jump Up connection.
Stub Connection straight into Maintenance Hole.
TwinJumpUp Twin Jump Up connection.
TwinRampRiser Twin Ramp Riser connection.
Chainage_m Float_Positive_Zero
Required

The distance in metres from the centre of the downstream manhole to the point of connection of the offshoot branch.

Offset_m Float_Positive_NonZero
Required

The distance measured square from the centre of the sewer main to the point of connection.

LineNumber String_32
Optional

The line identifier of the sewer main.

DSMHID String_32
Optional

Downstream manhole identifier.

IO_Distance_m Float_Positive_NonZero
Required

Distance from a point perpendicular to the inspection opening to the centre of the downstream manhole along the axis of the sewer main.

SO_Nearest_m Float_Positive_NonZero
Required

Perpendicular distance from the inspection opening to the nearest cadastral boundary.

SO_Other_m Float_Positive_NonZero
Required

Perpendicular distance from the inspection opening to the next nearest cadastral boundary.

Sediment_Trap boolean
Required

True indicates that the connection includes an inline sediment trap.