WaterSupply / ADAC Version v4.2

Pipe

Represents a water supply pipe feature.

ADAC
ADAC Versions

Attributes

Required and optional XML attributes
Use enum
Required

The purpose of this feature in the network.

Accepted Values
ValueDescription
Conduit Service Conduit.
FireService Fire service.
RawWater Raw Water Pipe.
Reticulation Reticulation Pipe. Default Value.
Scour Scour main.
Service Domestic Service.
Trunk Trunk Water Main.
Waste Waste Pipe.
FireDomestic Domestic Fire Service.
FireSprinkler Fire Sprinkler Service.
FireServiceThruMeter Fire Service Through Meter.
Irrigation Irrigation Pipe.
Alignment_m Float_Positive_NonZero
Optional

Offset from casdastral boundary to the main.

Diameter_mm positiveInteger
Required

Nominal diameter of the pipe in millimetres.

Material enum
Required

The pipe material.

Accepted Values
ValueDescription
DICL Ductile Iron Concrete Lined.
UPVC Unplasticised Poly Vinyl Chloride. Default Value.
ABS Acrylonitrile Butadiene Styrene.
CastIron CastIron
Concrete Concrete
Copper Copper
GRP Glass Reinforced Plastic (includes the product known commercially as Hobas).
MSCL Mild Steel Cement Lined.
OPVC Oriented Poly Vinyl Chloride.
Poly Polyethylene.
PVC-M Poly Vinyl Chloride - Modified.
RCP Reinforced Concrete Pipe.
LDPE Low Density Polyethylene.
MDPE Medium Density Polyethylene.
HDPE High Density Polyethylene.
Class enum
Optional

The pipe class as specified by the manufacture. Pipe class refers to the wall thickness and performance of the material.

Accepted Values
ValueDescription
16 Class 16. Default Value
6 Class 6.
9 Class 9.
12 Class 12.
18 Class 18.
20 Class 20.
K9 Class K9.
K12 Class K12.
SN5000 Class SN5000.
SN8000 Class SN8000.
SN10000 Class SN10000.
PN6.3 Class PN6.3.
PN10 Class PN10.
PN12.5 Class PN12.5.
PN16 Class PN16.
TypeA TypeA
Lining enum
Optional

The internal corrosion protection method employed on the pipe material.

Accepted Values
ValueDescription
CL Cement Lined normal (default for Ductile Iron and Mild Steel).
CL_SR Cement Lined - Sulphate Resistant (DI and MS).
CL_AC Cement Lined - Calcium Aluminate (DI and MS).
PVC PolyVinylChloride.
FBE Fusion Bonded Epoxy.
Unlined Unlined
Unknown Lining type unknown at time of data submission.
Other Another type of liner that is not currently in the Schema.
Protection enum
Optional

The external corrosion protection method employed on the pipe material.

Accepted Values
ValueDescription
FBE Fusion Bonded Epoxy.
Sintakote SINTAKOTE Fusion Bonded Medium Density Polyethylene.
SintakoteConcrete SINTAKOTE Fusion Bonded Medium Density Polyethylene. - Concrete Encased
ConcreteEncased ConcreteEncased
DensoTapeWrapped Wrapped in pipe and flange protection anti-corrosion tape. Commonly a synthetic fabric tape coated with a neutral petrolium compound.
Uncoated Uncoated.
JointType enum
Optional

Pipe jointing method employed.

Accepted Values
ValueDescription
RRJ Rubber Ring.
RRRJ Rubber Ring Restrained Joint (Ductile Iron).
SWJ Solvent Welded Joint (PVC)
WJ Welded Joint (Mild Steel pipe)
FJ Flanged Joint.
MCJ Mechanical Compression Joint (PE pipe and Copper).
BW Butt Weld (PE pipe).
EFW Electrofusion Weld (PE pipe).
JT_1 A new joint type not yet included in the Schema used by agreement with the receiving entity..
Unknown Joint type unknown at time of data submission.
Other A joint type not already included in the above choices.
AverageDepth_m float
Optional

The average depth in metres that the pipe is buried. This measure is useful in most residential developments, but will be less reliable in sharply changing terrain or where significant cuts and fills have been applied. Negative depths may be used to indicate exposed or suspended pipes above the surface.

Embedment enum
Optional

Embedment types.

Accepted Values
ValueDescription
Type A WSSA - Type A.
Type B WSSA - Type B.
Type C WSSA - Type C.
Type D WSSA - Type D.
Type E WSSA - Type E.
Type F WSSA - Type F.
Type G WSSA - Type G.
Type H WSSA - Type H.
Type J WSSA - Type J.
Type K WSSA - Type K.
Type L WSSA - Type L.
Type M WSSA - Type M.
Length_m Float_Positive_NonZero
Optional

Material length of the pipe in metres.

WaterQuality enum
Required

The quality of the water being carried by the pipe.

Accepted Values
ValueDescription
DrinkingWater Drinking-quality (potable) water for normal mains supply by the municipal water service provider.
RecycledAplus Class A+ tertiary treated with reverse osmosis recycled water for supply via dual reticulation for permitted interior and exterior uses.
RecycleA Class A tertiary treated recycled water for supply via dual reticulation for permitted exterior uses.
TreatedEffluent Treated Effluent to class B through class D for irrigation only.
RainWater Rain Water collected directly into the system for irrigation.
RawWater Untreated water from a watercourse or pond used to feed a water treatment plant or irrigation system.
GroundWater Untreated water from bores used to feed a water treatment plant or irrigation system.
ProcessWater Non-potable process water of some description.
Other Pipe conveying some other kind of water (not recycled class B and below which is considered as treated sewage effluent).
Unknown Type of water carried by this pipe is unknown at time of submission.